Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Chinese Journal of General Surgery ; (12): 108-112, 2022.
Article in Chinese | WPRIM | ID: wpr-933615

ABSTRACT

Objective:To investigate the efficacy and safety of comprehensive therapy in the treatment of advanced unresectable hepatocellular carcinoma.Methods:Clinical data of 34 patients with primary liver cancer admitted to Peking Union Medical College Hospital from Nov 2018 to Dec 2020 initially evaluated as unresectable were treated firstly by combined therapy and then underwent reevaluation for further management.Results:A total of 34 patients completed the integrative treatment, and no serious adverse events occurred. Among them, 6 patients were evaluated as partial remission, and underwent successful tumor resection, tumors in 7 patients were stable, and 21 patients suffered from disease progression.Conclusion:After comprehensive therapy, unresectable tumors in some patients could reduce and be rendered resection.

2.
Journal of Clinical Hepatology ; (12): 2380-2383, 2021.
Article in Chinese | WPRIM | ID: wpr-904952

ABSTRACT

Objective To investigate the value of optical trocar insertion technique in establishing pneumoperitoneum in patients undergoing laparoscopic surgery after previous abdominal surgery. Methods A total of 29 patients, with a history of abdominal surgery, who planned to undergo laparoscopic liver surgery were enrolled and randomly divided into optical trocar insertion group and open approach group. The independent samples t -test was used for comparison of normally distributed continuous data between groups, and the Mann-Whitney U test was used for comparison of non-normally distributed continuous data between groups; the Fisher's exact test was used for comparison of categorical data between groups; the Mann-Whitney U test was used for comparison of ranked data between groups. Results There were no procedure-related complications in either group. Compared with the open approach group, the optical trocar insertion group had a significantly shorter time required to establish pneumoperitoneum [35.00 (21.00-46.00) seconds vs 180.00 (152.50-252.50) seconds, U =0, P < 0.001] and a significantly smaller incision length [1.10(1.00-1.20) cm vs 2.80(2.45-3.00) cm, U =0, P < 0.001]. Conclusion Both optical trocar insertion and open approach for establishing pneumoperitoneum is relatively safe in patients undergoing laparoscopic liver surgery after previous abdominal surgery, while optical trocar insertion has the advantages of high efficiency and minimal invasiveness in establishing pneumoperitoneum.

3.
Journal of Clinical Hepatology ; (12): 2380-2383, 2021.
Article in Chinese | WPRIM | ID: wpr-904902

ABSTRACT

Objective To investigate the value of optical trocar insertion technique in establishing pneumoperitoneum in patients undergoing laparoscopic surgery after previous abdominal surgery. Methods A total of 29 patients, with a history of abdominal surgery, who planned to undergo laparoscopic liver surgery were enrolled and randomly divided into optical trocar insertion group and open approach group. The independent samples t -test was used for comparison of normally distributed continuous data between groups, and the Mann-Whitney U test was used for comparison of non-normally distributed continuous data between groups; the Fisher's exact test was used for comparison of categorical data between groups; the Mann-Whitney U test was used for comparison of ranked data between groups. Results There were no procedure-related complications in either group. Compared with the open approach group, the optical trocar insertion group had a significantly shorter time required to establish pneumoperitoneum [35.00 (21.00-46.00) seconds vs 180.00 (152.50-252.50) seconds, U =0, P < 0.001] and a significantly smaller incision length [1.10(1.00-1.20) cm vs 2.80(2.45-3.00) cm, U =0, P < 0.001]. Conclusion Both optical trocar insertion and open approach for establishing pneumoperitoneum is relatively safe in patients undergoing laparoscopic liver surgery after previous abdominal surgery, while optical trocar insertion has the advantages of high efficiency and minimal invasiveness in establishing pneumoperitoneum.

4.
Acta Academiae Medicinae Sinicae ; (6): 74-79, 2017.
Article in English | WPRIM | ID: wpr-277896

ABSTRACT

Objective To compare measurements of dual-energy CT iodine map parameters and liver perfusion CT parameters in patients with focal liver lesions using a third-generation dual-source CT scanner. Methods Between November 2015 and August 2016,33 patients with non-cystic focal lesions of liver were enrolled in this study. CT examinations were performed with a third-generation dual-source CT. The study CT protocol included a perfusion CT and dual-energy arterial and portal venous scans,with a time interval of 15 minutes. Iodine attenuation was measured at five region of interests including areas of high,medium,and low density within the lesion,as well as right and left liver parenchyma from the iodine map,while arterial liver perfusion (ALP),portal venous liver perfusion (PVP),and hepatic perfusion index (HPI) at the same location were measured from perfusion CT. The Pearson product-moment correlation coefficient was used to evaluate the relationship between iodine attenuation and perfusion parameters. Results The iodine attenuation at arterial phase showed significant intra-individual correlation with ALP (r=0.812,95% CI=0.728-0.885,P<0.001)and PVP (r=-0.209,95% CI=-0.323--0.073,P=0.007),but not significantly correlated with HPI (r=0.058,95% CI=0.046-0.498,P=0.461). The iodine attenuation at portal venous phase showed significant correlation with PVP (r=0.214,95% CI=0.072-0.361,P=0.005) but not with HPI(r=0.036,95% CI=-0.002-0.242,P=0.649). The mean effective dose of arterial phase and portal venous phase of dual-energy CT together [(3.53±1.17)mSv] was significantly lower than that of the perfusion CT [(14.53±0.45)mSv](t=25.212,P<0.001). Conclusion Iodine attenuation from arterial phase of dual energy CT demonstrates significant correlation with ALP and PVP,and iodine attenuation from portal venous phase demonstrates significant correlation with PVP.


Subject(s)
Humans , Contrast Media , Iodine , Liver , Diagnostic Imaging , Pathology , Perfusion , Portal Vein , Tomography, X-Ray Computed , Methods
SELECTION OF CITATIONS
SEARCH DETAIL